Inspection |
1. |
Remove the front door trim.
(Refer to Body - "Front Door Trim")
|
2. |
Remove the front door module.
(Refer to Body - "Front Door Module")
|
3. |
Disconnect the connectors from the actuator.
|
4. |
Check actuator operation by connecting power and ground according to
the table. To prevent damage to the actuator, apply battery voltage
only momentarily.
|
1. |
Remove the rear door trim.
(Refer to Body - "Rear Door Trim")
|
2. |
Remove the rear latch.
(Refer to Body - "Rear Door Latch")
|
3. |
Disconnect the connectors from the actuator.
|
4. |
Check actuator operation by connecting power and ground according to
the table. To prevent damage to the actuator, apply battery voltage
only momentarily.
|
1. |
Remove the tailgate trim.
(Refer to Body - "Tailgate Trim")
|
2. |
Disconnect the 4P connector from the actuator.
|
3. |
Check actuator operation by connecting power and ground according to
the table. To prevent damage to the actuator, apply battery voltage
only momentarily.
|
1. |
Remove the tailgate trim.
(Refer to Body - "Tailgate Trim")
|
2. |
Disconnect the switch connector.
|
3. |
Check for continuity between the terminals in each switch position according
to the table.
|
1. |
Disconnect the connector (A) and bolts from the hood switch.
|
2. |
Check for continuity between the terminals and ground according to the
table.
|
1. |
Remove the burglar horn (A) after removing a bolt and disconnect the
2P connector from the burglar horn.
|
2. |
Test the burglar horn by connecting battery power to the terminal 1
and ground the terminal 2.
|
3. |
The burglar horn should sound. If the burglar horn fails to sound replace
it.
|
Hyundai Creta GS 2014-2025 Service Manual: Description and operation
Description
Emissions Control System consists of three major systems.
•
The Crankcase Emission Control System prevents blow-by gas from releasing
into the atmosphere. This system recycles gas back into the intake manifold
(Closed Crankcase Ventilation ...
Hyundai Creta GS 2014-2025 Service Manual: Blower Motor: Repair procedures
Inspection
1.
Connect the battery voltage and check the blower motor rotation.
2.
If the blower motor does not operate well, substitute with a known-good
blower motor and check for proper operation.