Hyundai Creta: General Information / Specifications

Specification
Ignition System
Ignition Coil
Item
Specification
Primary Coil Resistance (Ω)
0.75 ± 15% [20°C (68°F)]
Secondary Coil Resistance (kΩ)
5.9 ± 15% [20°C (68°F)]

Spark plug
Item
Specification
Type
LZKR6B-10E, RER8MC, ELR9QC10
Gap
0.9 ~ 1.0 mm
(0.0354 ~ 0.0394 in)

Condenser
Item
Specification
Capacitance (uF)
0.47 [1KHz]
Insulation resistance (MΩ)
1,000 [DC 500 V/1 Min]

Charging System
Alternator
Item
Specification
Rated voltage
13.5V, 110A
Speed in use
1,000 ~ 18,000 rpm
Voltage regulator
IC Regulator built-in type
Regulator Setting Voltage
External mode
Refer to below graph
Internal mode
14.55 ± 0.3V
Temperature Gradient
External mode
0 ± 3 mV / °C 
Internal mode
-3.5 ± 2mV / °C

※ Regulator Setting Voltage (External mode)
Battery
▷MF45L-BCI : OPENABLE
Item
Specification
Model type
MF45L-BCI
Cold Cranking Amperes (A)
410 (SAE)
Reserve Capacity (Min)
80

▷MF60L-BCI : OPENABLE
Item
Specification
Model type
MF60L-BCI
Cold Cranking Amperes (A)
550 (SAE)
Reserve Capacity (Min)
92

▷MF68L-BCI : OPENABLE
Item
Specification
Model type
MF68L-BCI
Cold Cranking Amperes (A)
600 (SAE)
Reserve Capacity (Min)
110

  
Model type description

Cold Cranking Ampere (CCA) : Cold Cranking Amps is a rating used in the battery industry to define a battery's ability to start an engine in cold temperatures.
The rating is the number of amps a new, fully charged battery can deliver at -18 °C(-0.4 °F) for 30 seconds, while maintaining a voltage of at least 7.2 volts for a 12 volt battery.
The higher the CCA rating, the greater the starting power of the battery.
RESERVE CAPACITY (RC) : Reserve Capacity is a battery industry rating, defining a battery's ability to power a vehicle with an inoperative alternator or fan belt.
The rating is the number of minutes a battery at 26.7 °C(80 °F) can be discharged at 25 amps and maintain a voltage of 10.5 volts for a 12 volt battery.
The higher the reserve rating, the longer your vehicle can operate should your alternator or fan belt fail.
Starting System
Starter
Item
Specification
Rated voltage
12 V, 0.8 kW
The number of pinion teeth
9
Performance
[No-load, 11.5 V]
Ampere
Max. 65A
Speed
Min. 2715 rpm

Tightening Torques
Item
N.m
kgf.m
lb-ft
Ignition coil installation bolt
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Spark plug installation
14.7 ~ 24.5
1.5 ~ 2.5
10.9 ~ 18.1
Condenser & Hanger bracket installation bolt
18.6 ~ 23.5
1.9 ~ 2.4
13.7 ~ 17.4
Alternator mounting upper bolt
19.6 ~ 26.5
2.0 ~ 2.7
14.5 ~ 19.5
Alternator mounting lower bolt
29.4 ~ 41.2
3.0 ~ 4.2
21.7 ~ 30.4
Alternator brace mounting bolt
19.6 ~ 26.4
2.0 ~ 2.7
14.5 ~ 19.5
Battery (+) terminal tightening nut
7.8 ~ 9.8
0.8 ~ 1.0
5.2~ 8.7
Battery (-) terminal l tightening nut
3.9 ~ 5.9
0.4 ~ 0.6
2.9 ~ 4.3
Battery mounting bracket bolt
9.8 ~ 14.7
1.0 ~ 1.5
7.2 ~ 10.9
Battery tray installation bolt
8.8 ~ 13.7
0.9 ~ 1.4
6.5 ~ 10.1
Battery sensor cable installation bolt
21.6 ~ 32.4
2.2 ~ 3.3
15.9 ~ 23.9
Starter installation bolt
49.0 ~ 63.7
5.0 ~ 6.5
36.2 ~ 47.0

General information
The Micro 570 Analyzer The Micro 570 Analyzer provides the ability to test the charging and starting systems, including the battery, starter and alternator. ...

Troubleshooting
Troubleshooting Ignition System Symptom Suspect Area Remedy Engine will not start or is hard to start (Cranks OK ...

Other information:

Hyundai Creta GS 2014-2024 Service Manual: Input Speed Sensor
Description and operation Description • Input speed sensor uses an electric current type hall sensor in which the current is changed by the magnetic variation. • Input speed sensor (A) and output speed sensor are integrated an ...

Hyundai Creta GS 2014-2024 Service Manual: Repair procedures
Service Adjustment Procedure Steering Wheel Play Inspection 1. Turn the steering wheel so that the front wheels are placed in the straight ahead position. 2. Measure the distance that the steering wheel is turned ...

© 2017-2024 www.hcrmangs.com