Hyundai Creta: Charging System / Battery Sensor

Description and operation

Description
Vehicles have many control units that use more electricity. These units control their own system based on information from diverse sensors. It is important to have a stable power supply as there diverse sensors giving a variety of information. Battery sensor (A) is mounted on battery (-) terminal. It transmits battery voltage, current, temperature information to ECM. ECM controls generating voltage by duty cycle based on these signals.

Repair procedures

Removal
1.
Disconnect the battery negative (-) cable.
2.
Disconnect the battery sensor connector (A).
3.
Remove the battery negative (-) cable after removing the bolt (B).

Installation
1.
Install in the reverse order of removal.
Battery sensor cable installation bolt :
21.6 ~ 32.4 N.m (2.2 ~ 3.3 kgf.m, 15.9 ~23.9 lb-ft)
Battery (-) terminal l tightening nut :
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)
Battery
Description and operation Description 1. The MF(Maintenance Free) battery is, as the name implies, totally maintenance free and has no removable battery cell caps ...

Starting System
...

Other information:

Hyundai Creta GS 2014-2019 Owners Manual: Checking the brake/clutch fluid level
Check the fluid level in the reservoir periodically. The fluid level should be between MAX (Maximum) and MIN (Minimum) marks on the side of the reservoir. Before removing the reservoir cap and adding brake/clutch fluid, clean the area around the reservoir cap thoroughly to prevent b ...

Hyundai Creta GS 2014-2019 Service Manual: Specifications
Specifications Items Specifications Rated voltage DC 12V Operating voltage DC 9 ~ 16V Operating temperature -30°C ~ 75°C (-4°F ~ 158°F) Dark current ...

© 2017-2026 www.hcrmangs.com