Hyundai Creta: Blower / Blower Resistor (Manual): Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

4.
Install in the reverse order of removal.
Blower Motor: Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substi ...

Power Mosfet (DATC)
Description and operation Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor. Repair procedures ...

Other information:

Hyundai Creta GS 2014-2025 Service Manual: Components and components location
Components Location [LHD] 1. Sub frame 2. Steering gearbox 3. Front stabilizer bar 4. Front lower arm 5. Front axle 6. Front strut assembly 7. Drive shaft [RHD] 1. Sub frame 2. Steering gearbo ...

Hyundai Creta GS 2014-2025 Service Manual: Turn Signal Lamp: Repair procedures
Removal Door Mirror Turn Signal Lamp 1. Disconnect the negative (-) battery terminal. 2. Remove the mirror holder (A) from the outside mirror assembly.    ...