Hyundai Creta: Blower / Blower Motor: Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
Replace the blower motor if it is proved that there is a problem with it.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the blower motor connector (A) and then remove the blower motor (B) after loosening the screws.

3.
Install in the reverse order of removal.
Blower Unit
Components and components location Component Location 1. Blower unit assembly Components 1. Inlet Seal 2. Intake duct case ...

Blower Resistor (Manual): Repair procedures
Inspection 1. Measure the resistance between the terminals. 2. The measured resistance is not within specification, the blower resistor ...