Hyundai Creta: Blower / Blower Resistor (Manual): Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

4.
Install in the reverse order of removal.
Blower Motor: Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substi ...

Power Mosfet (DATC)
Description and operation Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor. Repair procedures ...

Other information:

Hyundai Creta GS 2014-2021 Service Manual: Rear Glass Defogger Switch: Repair procedures
Inspection 1. The windshield deicer switch inputs can be checked using the GDS. 2. To check the input value of windshield deicer switch, select option "Body Control Module". 3. Select option &quo ...

Hyundai Creta GS 2014-2021 Service Manual: Repair procedures
Inspection 1. After disconnecting the vapor hose from the PCV valve, remove the PCV valve. 2. Reconnect the PCV valve to the vapor hose. 3. Run the engine at idle, then put a finger over the open end of th ...