| Inspection |
| 1. |
Disconnect the battery negative terminal.
|
| 2. |
Remove the fuse box cover.
|
| 3. |
Remove the starter relay (A).
|
| 4. |
Using an ohmmeter, check that there is continuity between each terminal.
|
| 5. |
Apply 12V to terminal 85 and ground to terminal 86.
Check for continuity between terminals 30 and 87.
|
| 6. |
If there is no continuity, replace the starter relay.
|
| 7. |
Install the starter relay.
|
| 8. |
Install the fuse box cover.
|
StarterHyundai Creta GS 2014-2019 Service Manual: General information
The Micro 570 Analyzer
The Micro 570 Analyzer provides the ability to test the charging and starting
systems, including the battery, starter and alternator.
※ Because of the possibility of personal injur ...
Hyundai Creta GS 2014-2019 Service Manual: Schematic diagrams
Schematic diagram
Terminal Function
ABS Connector Input/ Out put
Wire No.
Designation
Current12V(AMPS)
max.permissible wire resistance (OHMS)
13
Ground for recirculation pump
...